Description
ICM291 DSI Furnace Control Board
Low cost form, fit and functional replacement for Carrier: LH33WP003A
Direct Spark Ignition (DSI) control board
Microprocessor-based
Controls combustion, blower and indorr fan motors; spark ignitor; and the gas valve
Monitors timing, trial for ignition, flame sensing and lockout
100% lockout safety feature
Compatible with LP or Natural Gas
Status LED for fault
Specifications
Control Voltage: 24 VAC (18-30 VAC), 60Hz
Line Voltage: 208/230 VAC, 60Hz
Timing
Pre-Purge: 45 seconds
Trial for Ignition: 5+2 seconds
Retry Period: Every 20 seconds for 15 minutes
Lockout: Manual reset
Post-Purge: 45 seconds
LED Indicators
Red LED: Steady ON-normal operation; Flashing-fault codes
Input
Power: RT and C
Thermostat Interface: R,W, and G
Safety Switches: RS, LS, and CS
Combustion Motor Hall Effect Sensor
Flame Sensing
Outputs
Spark
Gas Valve: GV
Combustion Motor: CM
Blower Motor: BM
Indoor Fan Motor: IFO